201 Daktronics Dr. PO Box 5128 Brookings SD 57006 Tel 888-DAK-SIGN (888-325-7446) Fax 605-697-4700 www.daktronics.com Fuelight™ FL-2109 Seri
4 Mechanical Installation Fuelight™ Petroleum digit displays are designed to operate in ambient temperatures ranging from -40oF to +120oF. However,
Power Installation 5 Section 3: Power Installation Important Notes: • Only a qualified individual should terminate power and signal cable at the d
6 Power Installation 3.2 Grounding Displays MUST be grounded according to the provisions outlined in any applicable local and national electrical c
Power Installation 7 3.3 Power Installation The Daktronics Fuelight™ displays are installed using the provided ground and neutral conductors. For t
Signal Installation 9 Section 4: Signal Installation 4.1 Signal Installation LED Driver In the display, the LED driver performs the task of switch
10 Signal Installation Driver Rotary Switch Line and Face Settings The first driver at each display installation is designated as a host driver – th
Control Options 11 Section 5: Control Options The FLR-100, FLR-500, FLR-1500, and FLD-2000 (indoor or outdoor) control kits can be used to change p
12 Control Options 5.2 FLR-500 Control Kit The FLR-500 control kit includes a radio transmitting device, a radio receiving device, and all hardware
Control Options 13 Petroleum Price Display Startup To operate the Fuelight™ Petroleum Price displays, the transmitter must first be programmed to th
14 Control Options Modifying Price Line Settings The petroleum price can be modified either by pressing the <EDIT> key during operation or usi
Control Options 15 Dimming The dimming level of the display can be adjusted in two ways. A light sensor mounted in the display driver can detect the
16 Control Options DIMMING BLANK SIGN ↓ BLANK THE SIGN? <ENT> YES <CLR> NO Press <ENTER> to accept this option. The next LC
Control Options 17 FLD-2000 Connection to the Display (Outdoor and Indoor) The Fuelight™ displays may be controlled from a location inside a buildin
18 Control Options DM-100 Insert and Code The DM-100 uses a keypad insert to program price information for Daktronics LED Fuelight™ Displays. The DM
Control Options 19 DM-100 Controller Operation The Petroleum Price Controller LCD display will default to showing the current display settings on po
20 Control Options To access Menu Items: 1. Press the <MENU> key. 2. Press the number of the desired menu item. • Use Menu Items 1-5 to edi
Control Options 21 If AUTOMATIC dimming is selected, the following LCD prompt will appear: LCD Screen Action SET AUTO DIMMING MAX INTENSITY?
Maintenance and Troubleshooting 23 Section 6: Maintenance and Troubleshooting Important Notes: • Disconnect power before any repair or maintenance
DD1398926 Product 1478 Rev 4 – 22 July 2011 Complete the chart with specific information about this display so the details are readily
24 Maintenance and Troubleshooting 6.2 Display Diagnostics Driver Diagnostic LEDs The driver has five LEDs that indicate whether it is functioning
Maintenance and Troubleshooting 25 6.3 Troubleshooting This chart lists some symptoms that may be encountered with the displays. For each symptom,
Replacement Parts 27 Section 7: Replacement Parts Important Notes: • Disconnect power before any repair or maintenance is done on the display. •
Exchange and Repair Program 29 Section 8: Daktronics Exchange and Repair & Return Programs 8.1 Exchange Program The Daktronics Exchange Progra
30 Exchange and Repair Program 8.2 Repair & Return Program For items not subject to exchange, Daktronics offers a Repair & Return Program.
Glossary 31 Glossary Cabinet: The metal body of a display. Client Driver: All drivers not designated as the host driver. The host receiver sends the
Reference Drawings 33 Appendix A: Reference Drawings This manual refers to drawings by listing the last set of digits and the letter preceding them
Warranty and Limitation of Liability 35 Appendix B: Daktronics Warranty and Limitation of Liability
Table of Contents i Table of Contents Section 1: Introduction ...
ii Table of Contents DM-100 Insert and Code ... 18 Petro
Introduction 1 Section 1: Introduction This manual explains the installation, maintenance, and troubleshooting of Daktronics Fuelight™ FL-2109 Outd
2 Introduction Fuelight™ outdoor LED displays have been designed for use with FLR-100, FLR-500, FLR-1500 and FLD-2000 communication kits. In this ma
Mechanical Installation 3 Section 2: Mechanical Installation Important Notes: • Read and understand these instructions before installing the displ