Daktronics KE-1010-7.6-RG User Manual

Browse online or download User Manual for Monitors Daktronics KE-1010-7.6-RG. Daktronics KE-1010-7.6-RG User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - DakTicker

Website: www.daktronics.com Tel 866-343-3122 Fax 605-697-4444 331 32nd Ave PO Box 5128 Brookings SD 57006 DakTicker® KE-1010 Series GEN II Installa

Page 2 - and DataStreamer

2.2 Display Mounting • It is the customer’s responsibility to ensure that the installation will meet local standards. • The mounting hardware must

Page 3 - Table of Contents

Display Distance From Display Top To Bottom Bracket Attachment Point KE-1010-16x***-7.62 0’-10 ¼” (260 mm) KE-1010-24x***-7.62 0’-13 ¼” (337 mm)

Page 5 - List of Figures

Section 3: Power Installation • Only a qualified individual should terminate power and signal cable at this Daktronics display. • All proposed chan

Page 6

Power Specifications for Tickers with Multiple Sections # of Phases 16 and 24 High Twin 16 High Amps Per Line (100-240VAC) 6.9 (Sum of 3 Sections

Page 7 - Section 1: Introduction

Section 4: Signal Installation To display messages on a KE-1010 display, signal is sent from the computer to the ticker via one of two possible netwo

Page 8 - 1.3 Safety Precautions

RS-422 Pin-outs The controller’s RS-422 jacks have the following pin-outs: Signal Installation 10 OUTPUT (J5) RJ11 Function 1 N.C. 2 D2OUT-N 3 D2OU

Page 9 - Figure 5: Mounting Options

Ethernet Connections For DakTickers using an Ethernet system for communication, a network connection will be made from the network hub or switch to t

Page 10 - 2.2 Display Mounting

4.2 Section to Section Connections The signal between the master and echo sections is connected using 20-pin ribbon cables between the shift board an

Page 11

Figure 16: Master to Master RS-422 Connection 4.4 Installation Checklist After installation is complete, go over these steps to make sure that the

Page 12

ED-15353 Product 1182 Rev 1 – 27 April 2007 Fill in the chart with specific information about this display so the

Page 14 - 3.2 Power Cord - Grounding

Section 5: Maintenance and Troubleshooting This section covers the basic maintenance needed to keep the display operating effectively. Also included

Page 15 - 4.1 Network Options

Maintenance and Troubleshooting 16 Visual Structural Inspection At least once a year, check the display to make sure that the structure and compone

Page 16

Maintenance and Troubleshooting 17 5.3 Definitions Cabinet: The metal frame of the display (back, bottom, top); may also include the end caps.

Page 18 - Figure 14: Shift Board

Section 6: Parts Replacement • Disconnect power before any repair or maintenance work is done on the display! • Qualified service personnel must m

Page 19 - 4.5 Boot Up Sequence

Parts Replacement 20 Consult this list for the Daktronics part number for basic display components. Refer to Section 6.4 for instructions on obtainin

Page 20

6.2 Removing the Face Panel The internal components of the KE-1010 displays may be accessed after the face panel and modules are removed. Refer to

Page 21 - 5.1 Display Maintenance

6.3 Instructions for Replacing Parts LED Module Replacement To remove and replace an LED module: 1. Disconnect the main supply power to the section

Page 22 - 5.2 Troubleshooting

Power Supply Replacement Power to the LED modules is provided by +5 VDC power supplies. To remove a power supply: 1. Disconnect the main supply pow

Page 23 - 5.3 Definitions

Table of Contents i Table of Contents Section 1: Introduction...

Page 24

Controller Replacement The controller is mounted inside the master display on the back of the cabinet (Figure 24). It is typically located behind the

Page 25 - 6.1 Replacement Parts List

Parts Replacement 25 Controller Address The controller has a set of “DIP” switches or address switches, as shown in Figure 24. These switches set

Page 26

Parts Replacement 26 To participate in the Exchange Program, follow these steps: 1. Call Daktronics Customer Service: 866-343-3122 2. When the n

Page 27

Reference Drawings 27 Appendix A: Reference Drawings Drawings are inserted here according to this list, with generic drawings first, followed by C

Page 34

Table of Contents ii 6.4 Daktronics Exchange and Repair & Return Program ...25 Exchange Prog

Page 45

List of Figures Figure 1: KE-1010 Display...

Page 53

Signal Converter 29 Appendix B: Signal Converter Signal Converters and Loop-back Testing for Direct Connections The following table gives the typ

Page 54

RS-422 Wire Signal Converter The following tables list the jack pin-outs for a wire signal converter: J4 and J5 – Phoenix PIN OPERATION 1 GND 2 RX-P

Page 55

RS-422 Loop-Back Test (Indoor/Outdoor Displays) All indoor displays and some outdoor displays (AE-3010, AF-3010, AF-3020, and X-1000) use RJ11 plugs

Page 57 - Appendix B: Signal Converter

32 Signal Converter Electrical and Signal Information WARNINGS: • Never install telephone wiring during a lightning storm. • Never touch uninsu

Page 58 - Converter

Mounting Instructions The signal converter can be either wall or table mounted. Do not mount the signal converter from the ceiling or the underside

Page 59 - 3. When both ends are

Section 1: Introduction The Daktronics DakTicker™ KE-1010 displays are designed and manufactured for performance, reliability, easy maintenance, and

Page 60 - Environmental Rating

A module is the building block of the DakTicker display. By placing modules side-by-side, a display of any length can be designed and built. Individua

Page 61 - Mounting Instructions

Section 2: Mechanical Installation Mechanical installation includes both support structure design and mounting methods. Two mounting methods are expl

Comments to this Manuals

No comments