18 Network and Communication Installation
Conguration Steps
1. Install USB-to-Ethernet adapter driver on computer.
2. Establish a link between the adapter and the display.
3. Turn display on.
4. Launch DisplayFind and discover the display.
5. Once the display is found, click the link to launch the conguration utility.
6. Click Logon to connect to the display (refer to the help le for additional information about
the conguration utility).
7. Congure the displays IP address to:
IP Address: 172.16.192.25
Subnet Mask: 255.255.0.0
8. Click UploadConguration.
9. Log out of the conguration utility.
10. Turn display off.
11. Congure IP address on USB-to-Ethernet adapter to:
IP Address: 172.16.192.20
Subnet Mask: 255.255.0.0
12. Turn display on.
13. Congure display in Venus 1500 software.
8.7 Standard Communication Options
Daktronics GalaxyPro
®
GP3 displays can receive various forms of Ethernet communication.
The standard communication options are listed below along with the communication-specic
document numbers. For additional information regarding communication installation, refer to
these documents, which are provided with the communication kits.
Communication Type Manual Document Number Quick Guide Document Number
Ethernet – Wire DD1417609 DD1417573
Ethernet – Fiber DD1417611 DD1417581
Ethernet Bridge Radio DD1685027 DD1417586
These are the standard communication types, but each site is unique and may include additional
equipment. For questions, contact Daktronics Technical Support.