Venus 1500 Controller
Version 2
Operation Manual
ED-12717
InfoNetä, DataTracä, and Galaxyä are trademarks and Glow Cube
â
, Venus
â
and SunSpot are registered
trademarks of Daktronics, Inc. All other trademarks are the property of their respective companies.
ED-12717
Product #1147
Rev. 2 – 18 December 2001
Copyright ã 2001 Daktronics, Inc.
All rights reserved. While every precaution
has been taken in the preparation of this
manual, the publisher assumes no
responsibility for errors or omissions. No part
of this book covered by the copyrights
hereon may be reproduced or copied in any
form or by any means - graphic, electronic,
or mechanical, including photocopying,
taping, or information storage and retrieval
systems - without written permission of the
publisher.
DAKTRONICS, INC.
P.O. Box 5128 331 32
nd
Ave. Brookings, SD 57006
Phone (605) 697-4033 or (877) 605-1112 Fax 697-4444
www.daktronics.com e-mail helpdesk@daktronics.com
Page view 0
1 2 3 4 5 6 ... 68 69

Summary of Contents

Page 1 - DAKTRONICS, INC

Venus 1500 Controller Version 2 Operation Manual ED-12717 InfoNetä, DataTracä, and Galaxyä are trademarks and Glow Cubeâ, Venusâ an

Page 2

TCP/IP Connection Type: Display connection across an Ethernet network using the TCP/IP protocol. This type of connection requires a serial server devi

Page 3 - Table of Contents

When creating a new or opening an existing message/schedule, a small box will be visible to the left of each display type. When the box is filled wit

Page 5

Section 2: Installation The Venus 1500 software must be installed to a hard disk before use. To install the software onto a computer, follow these

Page 7 - Section 1: Introduction

Section 3: Configuring the Venus 1500 Controller for First Time Use LThis section is intended to provide basic instructions and examples to configu

Page 8 - 1.4 Definitions

3.1 Adding a Direct Connection Network The simplest type of network to use is a “direct” network. On this type of network, a dedicated wire connecti

Page 9 - ENTER> on the keyboard

box. Select Galaxy (LED). The fields in the lower half of the dialog box will adjust based on the selected type of technology. 4. Use the drop-down

Page 11 - 1.8 Contacting Daktronics

Section 4: The Venus 1500 Administrator The Venus 1500 Administrator is used to configure the various displays, display types, display groups and n

Page 13 - Section 2: Installation

4.1 Adding a Network The Venus 1500 Administrator 4-2 Click on to activate the network configuration screen. Right-click on any of the network na

Page 14

1. To use this type of connection, select Dialup Networks in the Network Type field, if it is not already selected. 2. Click on the down arrow next

Page 15

4. If a Lantronix serial server is being used, click on Use Default. Otherwise, enter the socket number in the corresponding box. 5. Click on [OK] t

Page 16 - 3.2 Adding the Display Type

4.5 Communication Defaults (Networks) The operator can specify default settings for timeouts, maximum retries and disconnect time for each of the ne

Page 17 - 3.3 Adding a Display

sizes and colors for the current display technology will be available for selection. If the display is a DataTrac, enter the color (monochrome or tri

Page 18

1. From the Edit pull-down menu, select New and then Display, or right-click on a display type or another existing display name and select New and th

Page 19

Editing a Display’s Configuration To modify the settings of an existing display or display group, either right-click on a display or group name at the

Page 20 - 4.1 Adding a Network

4.9 Time Zone Offset Configuration This allows the time that is sent from the controlling PC to be offset according to Greenwich Mean Time (GMT) if

Page 22 - 4.4 Remote Database

Section 5: The Venus 1500 Message Studio The Venus 1500 Message Studio creates the messages that will appear on the displays. Text and graphics are

Page 23 - 4.6 Display Type

Table of Contents Section 1: Introduction... 1-1 1.1 Sys

Page 24 - 4.7 Displays

5.1 Opening an Existing Message To open an existing message, The Venus 1500 Message Studio 5-2 1. Click on the open button or select Open from t

Page 25 - LNote: Display types must be

Undo/Redo In Message Studio This tool can be used during the creation of a message to quickly undo an action up to the last ten steps. The Redo comma

Page 26 - REMOVE]. It is

The Venus 1500 Message Studio 5-4 Message On the toolbar above the Message Studio editing area, four buttons are used to add and delete frames. es tD

Page 27 - 4.10 Network Testing

The Venus 1500 Message Studio 5-5o invert the colors of a frame (red pixels turn green while green pixels turn red, etc. depending n display color),

Page 28

Specifying the Entry Effect For text frames, eight entry effects are available: Instant, Scroll Left, Scroll Right, Scroll Up, Scroll Down, Roll Up, R

Page 29 - Thumbnails

Graphic Toolbar You may notice that a grid is visible on the graphic frame. Each box represents a pixel on the display. The pixel dimensions of the

Page 30 - 5.2 Creating a New Message

5. Once the progress monitor disappears the import is complete. Adding Text-Objects To place text on a graphic frame: 1. Select the Text button fr

Page 31 - .4 Frames

The Effect Rate is the speed at which the frame entry effects occur. The Flash Rate is the speed at which flashing text will flash. Set either of thes

Page 32

5.12 Date, Time & Temperature Data Fields You can insert data fields into a message to display the date, time, temperature (if a temperature sen

Page 33 - Text Frames

ITF Files The top half of the dialog box is reserved for ITF files. ITF files consist of multiple RTD fields usually generated by the source program (

Page 34 - 5.7 Graphic Frames

Section 5: The Venus 1500 Message Studio...5-1 5.1 Opening an Existing Message...

Page 35 - Graphic Toolbar

Horn RTD Field The Horn RTD field controls the display’s horn, if one is installed. It is displayed for use with sporting applications, receiving RTD

Page 36 - 5.8 Frame Properties

5.15 Adding a Description The operator can add a description to a message to better explain or define what the message consists of or shows. From

Page 37 - 5.11 Drag and Drop

5.17 Deleting a Message To remove a message from the Message Studio: 1. From the File pull-down menu, select either Open or Save As. A dialog box

Page 38 - 5.13 Real Time Data (RTD)

Section 6: The Venus 1500 Schedule Studio The Venus 1500 Schedule Studio is used to configure schedules for the display(s). Messages and display br

Page 39

6.1 Starting a New Schedule To start a new schedule: 1. Select New from the File pull-down menu or click on . The New Schedule dialog box appears.

Page 40

6.3 Using the Schedule Studio When creating or editing a schedule, there are a few things to keep in mind. · Messages scheduled to run during the

Page 41 - 5.15 Adding a Description

For example, if a message is to run from 11:00 PM to 1:00 AM, two events need to be entered. Event 1 would run from 11:00 PM (Start Time) to 11:59 PM

Page 42 - 5.17 Deleting a Message

6.4 Naming & Saving the Schedule To name (or rename) the schedule, click on the File pull-down menu and select Save As. The Save Schedule dialog

Page 43 - Venus 1500 Schedule Studio

6.6 Exiting the Venus 1500 Schedule Studio To exit the Schedule Studio, select Exit from the File pull-down menu. If any schedules have not been sav

Page 44 - 6.1 Starting a New Schedule

Entry No. Type Message Name Library Name The Message will Run… 1 Message Christms Holidays 24 hours per day, everyday from Dec. 1 through Dec. 25 2

Page 45

Choosing the Type of Event ...6-3 Message...

Page 47 - 6.5 Printing

Section 7: The Venus 1500 Display Manager The Venus 1500 Display Manager controls communications with the displays, is capable of basic display mon

Page 48 - 6.8 Sample Schedule

Display List The Display List shows all the displays configured for the Venus 1500 network. In addition to each display’s name, the list graphically i

Page 49

names with the mouse. Select a range of messages by pressing <SHIFT> while choosing the desired messages. Determining what Messages are Runnin

Page 50

Blanking the Display To stop all messages running on the display, click on . The display will now be completely blank. Retrieving a Message from a D

Page 51

7.2 Schedule Control Click on . The Venus 1500 Display Manager screen adjusts for Schedule Control. Venus 1500 Display Manager – Schedule Control

Page 52 - 7.1 Message Control

7.3 Diagnostic Control Click on . The Venus 1500 Display Manager screen adjusts for Diagnostic Control. The Venus 1500 Display Manager 7-6 Diagnos

Page 53

· InfoNet Displays (excluding model G-1000 Displays): Revision 14 or higher (Firmware Number ED-10133) · Venus 1500 Controlled DataTrac Displays: R

Page 54

7.5 Exiting the Display Manager To close and exit the Venus 1500 Display Manager, either click on in the upper right corner of the screen, or selec

Page 55 - 7.2 Schedule Control

Appendix A: System Riser Diagram Appendix A: System Riser Diagram A-1

Page 56 - 7.3 Diagnostic Control

C.3 Displaying the Font...C-3 Table of Contents iv

Page 60

Appendix B: Graphics & Special Characters The following table lists special characters that may be used when creating text by holding down on &l

Page 61

¡ <ALT> <1> <7> <3>█ <ALT> <2> <1> <9>ä <ALT> <2> <4> <0>ã <ALT> <2&g

Page 62

Electronic DisplayControl Software SystemDaktronics, Inc. 331 32nd Avenue, P.O. Box 5128, Brookings, SD57006 SL111302-04078 Page 1 of 27 Pixel Hig

Page 63

331 32nd Avenue, PO Box 5128, Brookings, SD 57006Phone: 800-DAKTRONICS or 605-697-4300 Fax: 605-697-4700website: www.daktronics.com email: sales@dak

Page 64

Appendix C: Using the Venus 1500 Controller to Display Non-English Fonts The Venus 1500 Controller is capable of displaying various non-English fon

Page 65 - Electronic Display

3. Double-click on Regional Options (Windows 2000) or Regional Settings (Windows NT). Windows 2000 1. At the bottom of the General tab is a sectio

Page 66 - Graphic Fonts Continued

C.3 Displaying the Font To create a graphic frame with the non-English fonts: 1. Create a new graphic frame in the Venus 1500 Message Studio (ref

Page 67 - C.2 Initial Settings

Section 1: Introduction The purpose of this manual is to assist in the installation and operation of the Venusâ 1500 Display Network. Refer to Appe

Page 68

1.4 Definitions The following are terms and definitions used throughout the manual and software. Apply: Clicking [APPLY] on some screens allows chan

Page 69 - C.3 Displaying the Font

Group: A group is a collection of displays of the same display type. The group may be selected instead of the individual displays. When displays belon

Comments to this Manuals