Daktronics AF-3160-34-R,A User Manual

Browse online or download User Manual for Monitors Daktronics AF-3160-34-R,A. Daktronics AF-3160-34-R,A User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 90
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Galaxy
®
Series
AF-3160
Display Manual
ED13767 Rev 2 10 February 2004
331 32
n
d
Ave PO Box 5128 Brookings SD 57006
Tel 605-697-4034 or 877-605-1113 Fax 605-697-4444
www.daktronics.com
Page view 0
1 2 3 4 5 6 ... 89 90

Summary of Contents

Page 1 - AF-3160

Galaxy® Series AF-3160 Display Manual ED13767 Rev 2 10 February 2004 331 32nd Ave PO Box 5128 Brookings SD 57006 T

Page 2 - DAKTRONICS, INC

Introduction 1-41.3 Display Overview Reference Drawings: Shop Drawing; AF-3160-8-32-34-Mono-Gen2... Drawing B-178625 Shop Drawing; AF-3160-4

Page 3 - Table of Contents

Controller: The controller is the “brains” of the display. Shown below in Figure 2, the controller receives signal information from the control comput

Page 4

Module: 34mm Galaxy modules are 8 pixels high by 8 pixels wide. Each is individually removable from the front of the display. Refer to the module in F

Page 5 - List of Figures

Figure 4: Signal Converter (RS232 to RS422) RS422: RS422 is a standard differential communication type with a maximum cable length of 4000 feet (1.2

Page 6

Finally, Daktronics part numbers are commonly found on drawings. Those part numbers can be used when requesting replacement parts from Daktronics Cus

Page 7 - Section 1: Introduction

Mechanical Installation 2-1Section 2: Mechanical Installation Daktronics does not guarantee the warranty in situations where the display is not cons

Page 8 - 1.2 Network Concepts

2.3 Ventilation Requirements Reference Drawings: Shop Drawing, AF-3160-8-32 -34-Mono-Gen2 ... Drawing B-178625 Shop Drawing, AF-3160-40/48**-3

Page 9 - Radio Network

Mechanical Installation 2-32.5 Display Mounting Reference Drawings: Shop Drawing, AF-3160-8-32 -34-Mono-Gen2...Drawing B-178625 Shop Drawing

Page 11 - Figure 2

Section 3: Electrical Installation Only a qualified individual should terminate power and signal cable within this Daktronics display. The Daktronic

Page 12 - Figure 3: 8x8 Red LED Module

ED13767 Product 1215 Rev 2 – 10 February 2004 DAKTRONICS, INC. Copyright © 2003-2004 All rights r

Page 13 - 1.5 Daktronics Nomenclature

Figure 11: Phoenix Connector 3. Phoenix™-Style Connectors: Phoenix-style connectors, which are usually green, are often used for signal termination

Page 14 - 0P-1195-0001

Electrical Installation 3-33.2 Control Cable Requirements RS232 This cable is a 2-conductor shielded cable used to transmit an RS232 signal (Daktron

Page 15

3.3 RJ Connector Cables Two types of RJ connectors are used in the display. There is the 6-pin RJ11 and the 8-pin RJ45. Figure 15 on the right illus

Page 16 - 2.4 Lifting the Display

3.4 Conduit Reference Drawings: Shop Drawing, AF-3160-8-32 -34-Mono-Gen2...Drawing B-178625 Shop Drawing, AF-3160-40/48**-34-Mono-Gen2...

Page 17 - 2.5 Display Mounting

Electrical Installation 3-66. Power conductors from the disconnect to the display should be routed through conduit in agreement with local code. 7.

Page 18

Figure 19: Display Grounding The grounding electrode is typically one grounding rod for each display face. Other grounding electrodes as described

Page 19

Installation with Only a Neutral Conductor Provided Installations where no grounding conductor is provided must comply with article 250-32 of the Nati

Page 20

Main Disconnect The National Electrical Code requires the use of a lockable power disconnect near the display. Provide a lockable disconnect switch (k

Page 21 - Fiber Optic

RS232 Reference Drawings: System Riser Diagram, RS232 ... Drawing A-174341 Schematic, Signal Wiring, Internal, W/Quic

Page 22 - 3.3 RJ Connector Cables

Figure 24: RS232 J-box to Controller Board J-Box to Controller Board (A31) J-Box Terminal Block Field Cabling Controller Board TB1 (RS232 In) Pin

Page 23 - 3.4 Conduit

Table of Contents iTable of Contents Section 1: Introduction...1-1

Page 24 - 3.6 Power

Figure 25: RS422 Display Layout Figure 26: Signal Converter to Surge Board Assembly Signal Converter to Surge Board Assembly Signal Converter

Page 25 - Power Installation

Modem Reference Drawings: System Riser Diagram, Modem...Drawing A-174342 Schematic, Signal Wiring, Internal, W/Quick

Page 26 - Power Connection

Fiber Optic Reference Drawings: System Riser Diagram Fiber ... Drawing A-174344 Schematic, Signal Wiring, Interna

Page 27 - Main Disconnect

Signal Converter to Fiber Board Signal Converter Field Cabling Fiber Control Card J2 Transmit (TX1) (Color Varies) J5 Receive (RX2) J3 Receive (RX

Page 28 - Figure 24 and

3.8 Signal Termination Between Two (or More) Signs Reference Drawings: System Riser Diagram Fiber ... Drawing A-1

Page 29

Electrical Installation 3-17Fiber Interconnection A fiber cable can be used in connecting two or more displays in the fiber interconnection method. C

Page 31 - Figure 27 for system layout

Section 4: Maintenance and Troubleshooting Important Notes: 1. Power must be turned off before any repair or maintenance work is done on the displa

Page 32

Maintenance and Troubleshooting 4-24.2 Signal Summary The signal routing for the display can be summarized as follows: 1. Data from the control com

Page 33 - Venus 1500 Radio

Maintenance and Troubleshooting 4-34.4 Service and Diagnostics Reference Drawings: Detail; AF-3160-8/16, Power/Control Corner...Drawing A

Page 34 - RS422 Interconnection

Table of Contents ii 3.10 First Time Operation... 3-17 Section 4: Main

Page 35 - 3.10 First Time Operation

Transformer and RFI Filter Reference Drawings: Assy, Power Termination Box ... Drawing A-127361 Schematics ...

Page 36

Controller Reference Drawings: Detail; AF-3160-8/16, Power/Control Corner...Drawing A-178959 Detail; AF-3160-24/32/40/48, Power/Control C

Page 37 - Troubleshooting

Maintenance and Troubleshooting 4-6Complete the following steps to remove the controller from the display: 1. Disconnect power from J5. 2. Remove

Page 38 - 4.3 Power Summary

Maintenance and Troubleshooting 4-7Four diagnostic LEDs are located on the controller; the table below tells what each LED denotes: CPU LED Colo

Page 39 - 4.4 Service and Diagnostics

Modules and Drivers Reference Drawings: Comp. Layout Diagrams... Refer to Appendix A The module and driver bo

Page 40 - Transformer and RFI Filter

Complete the following steps to remove a power supply from the display: 1. Remove the module directly in front of the failed power supply. 2. Disco

Page 41 - Controller

Modem Reference Drawings: Detail; AF-3160-8/16, Power/Control Corner ... Drawing A-178959 Detail; AF-3160-24/32/40/48, Power/Control Corne

Page 42

Fiber Board Reference Drawings: Detail; AF-3160-8/16, Power/Control Corner...Drawing A-178959 Detail; AF-3160-24/32/40/48, Power/Control

Page 43

1. To replace the surge board, first disconnect the signal connections (refer to Figure 42 on the right). Figure 42: RS422 Surge Suppressor 2. The

Page 44 - Power Supplies

The terminating jumper is located on the quick connect board on the inside of the display. Most displays have both an input and an output quick connec

Page 45 - Light Detector

List of Figures iii List of Figures Figure 1: Drawing Label ...

Page 46 - Figure 40 below for the

Maintenance and Troubleshooting 4-14To check the operation of the fans, push the bypass button (momentary contact) on the thermostat enclosure to tem

Page 47 - RS422 Surge Suppressor

entering the display. Also, check electronic components for possible corrosion. • Corrosion Check the paint, and look for possible corrosion especia

Page 48 - Figure 42 on the

Maintenance and Troubleshooting 4-164.10 Initialization Operation Information Every time the display is operated, the display will run through an in

Page 49

Maintenance and Troubleshooting 4-17Modem/Radio Interface J-box, signal converter 0A-1279-0168 Cables: Cable; 18” RJ11; 6-Cond.,Straight 0A-1137-0

Page 50 - 4.8 Display Maintenance

Maintenance and Troubleshooting 4-18If the replacement part fixes the problem, package the defective part in the same box and packaging in which the

Page 51 - 4.9 Troubleshooting

Appendix A: Reference Drawings A-1Appendix A: Reference Drawings Refer to Section 1.1 for information on reading drawing numbers. The following dra

Page 56

List of Figures iv Figure 35: Power Termination Box...4-4 Figure

Page 67

Introduction 1-1Section 1: Introduction This manual explains the installation, maintenance, and troubleshooting of a Daktronics Galaxy® 34mm monochr

Page 78

Figure 1: Drawing Label All references to drawing numbers, appendices, figures, or other manuals are presented in bold typeface, as shown below. “

Page 89

Introduction 1-3The common thread to most client requests is a means of programming and controlling a group of displays from a central control point.

Comments to this Manuals

No comments