6 OmniSport 2000 Connections Setup 2.2 Hy-Tek MEET MANAGER Settings Every OmniSport 2000 console connects to a separate computer running Hy-Tek MEE

Page 3 - Table of Contents

OmniSport 2000 Connections Setup 7 2. Enter the Serial Com Port that will be used to connect MEET MANAGER to the OmniSport 2000 console then click

Page 4

8 OmniSport 2000 Connections Setup 4. Refer to the settings in Figure 7 for an OmniSport 2000 console input. The only settings that change between

Page 5 - Section 1: Introduction

OmniSport 2000 Connections Setup 9 SwimDive Request II 1. From the main screen of the SwimDive Request II program (Figure 9), click the Port button

Page 6 - 1.3 Timing Systems

10 OmniSport 2000 Connections Setup 1. Using the M2Config application, verify the settings for ports 1-4. Select Network > Configure Connection.

Page 7 - 1.4 Results Software

Daktronics Matrix Displays with Colorado Timing Systems 11 Section 3: Daktronics Matrix Displays with Colorado Timing Systems This section assumes

Page 8

12 Daktronics Matrix Displays with Colorado Timing Systems 4. Enter the following information: Baud Rate: 9600, Parity: Even, Data Bits: 7 and St

Page 9 - 2.1 OmniSport 2000 Settings

Daktronics Matrix Displays with Colorado Timing Systems 13 5. Test Communications. From the Venus 7000 shell, click the Diagnostics RTD tab, select

Page 10 - Figure 3: Run the Meet

14 Daktronics Matrix Displays with Colorado Timing Systems 5. After opening the Timer Interface 2000 program again, click Add under the OUTPUTS: se

Page 11 - Figure 5: Venus 7000 Shell

Daktronics Matrix Displays with Colorado Timing Systems 15 3.3 Venus 1500 Control System Refer to DWG-604064 and DWG-604462 for general system layo

Page 12 - Figure 7: Edit RTD Input

DD1387596 Rev 2 – 16 April 2012 DAKTRONICS, INC. Copyright  2008-2012 All rights reserved. While every precau

Page 13 - Input Template Files

16 Daktronics Matrix Displays with Colorado Timing Systems 6. Back on the Input Properties screen (Figure 31) click ITF. The Select Input Template

Page 14

Daktronics Matrix Displays with Colorado Timing Systems 17 Timer Interface 2000 Settings 1. From the main menu of the Timer Interface 2000 program

Page 15 - Colorado Timing Systems

18 Daktronics Matrix Displays with Colorado Timing Systems Under Port Type: select UDP/IP. Under UDP Port, type in 3002. 8. Click OK in the Configu

Page 16 - Venus 7000 Settings

Daktronics Matrix Displays with Omega Timing Systems 19 Section 4: Daktronics Matrix Displays with Omega Timing Systems When interfacing an Omega

Page 17 - TimerInterface 2000 Settings

20 Daktronics Matrix Displays with Omega Timing Systems OSM6 or ARES 21 Set to UNT4 1. Connect a null modem cable from the Hy-Tek computer to the

Page 18 - Figure 24: Select Input

Daktronics Matrix Displays with Omega Timing Systems 21 To configure the RTD inputs in the Venus 7000 computer, click Configure from the Venus 7000

Page 19 - Venus 1500 Real Time

22 Daktronics Matrix Displays with Omega Timing Systems 3. The Enter Port Parameters window will open (Figure 39).Type the name of the input, for

Page 20 - Display RTD Inputs

Daktronics Matrix Displays with Omega Timing Systems 23 10. The TimerInterface 2000 screen shows each configured input and output (Figure 43). Fo

Page 22

How to Create RTD Sequences 25 Section 5: How to Create RTD Sequences 5.1 Venus 7000 1. Refer to Section 2.3 to verify the necessary Input Temp

Page 23 - Omega Timing Systems

Table of Contents i Table of Contents Section 1: Introduction ...

Page 24 - 4.2 Venus 7000 Settings

26 How to Create RTD Sequences 5.2 Venus 1500 Version 3.12 1. Begin by opening the V1500 Message Studio from the V1500 shell. Select File > New

Page 25

How to Create RTD Sequences 27 5. On the right there should be a story board with two frames, a blank Text Frame and a second Graphic Frame with R

Page 27

Daktronics Exchange and Repair & Return Programs 29 Section 6: Daktronics Exchange and Repair & Return Programs 6.1 Exchange Program The D

Page 28

30 Daktronics Exchange and Repair & Return Programs If the part or parts are returned within 2 weeks of the second invoice date, Daktronics will

Page 29 - 5.1 Venus 7000

Index 31 Index . E Extended requests Hy-Tek ... 7 O OSM6 Setup ...

Page 31 - Figure 49: Save Message

Appendix A 33 Appendix A: Reference Drawings Omni 2000 System to Galaxy via Wired Ethernet (Venus 1500) ... Drawing B-26

Page 34 - Shipping Address

ii Table of Contents Section 6: Daktronics Exchange and Repair & Return Programs ... 29 6.1 Exchange Pro

Page 41

               

Page 42



Page 43

Introduction 1 Section 1: Introduction This manual explains aquatics interfaces with Daktronics matrix displays and includes the following sections

Page 44

2 Introduction 1.2 Software Conventions The following terms are used to describe various mouse actions that can be used throughout this manual. Thes

Page 45

Introduction 3 1.4 Results Software Information for this manual assumes Hy-Tek MEET MANAGER is being used. If a different program is being used inst

Page 47

OmniSport 2000 Connections Setup 5 MENU-COMM PORTS RTD PORT: RTD* MENU-COMM PORTS RSLT: OMNI 2000* Section 2: OmniSport 2000 Connections S